The high-density fiber distribution cabinet is core infrastructure adapted to the harsh operating conditions of nuclear power plants and designed for highly reliable optical signal aggregation. Featuring high-density integration, strong environmental endurance and high safety redundancy, it is the key physical carrier for the stable operation of nuclear instrumentation & control (I&C) systems and data communication networks.
Send Mensahe Pagkuha Presyo
| Cabinet Material | Bugnaw nga Giligid nga Steel Sheet | Mga Dimensyon sa Gawas (mm) | 2500 × 800 × 600 | ||||||
| Kapasidad sa Fiber Tray | 1,440–2,880 ka mga Core | Timbang (kg) | |||||||
| Standard nga mga Accessories | |||||||||
| Dili | ngalan | Unit | Qty | Dili | ngalan | Unit | Qty | ||
| 1 | Lawas sa Gabinete | Ibutang | 1 | 6 | Asembliya sa Pag-ayo sa Kable | Ibutang | 2 | ||
| 2 | Mga Cable Tie (Naylon) | Pc | 60 | 7 | 1U Rack-Mount Splicing & Distribution Unit | Pc | 30 | ||
| 3 | Pagpalapad nga Anchor Bolts | Pc | 4 | 8 | |||||
| 4 | Splice Protection Sleeve | Pc | 2880 | 9 | |||||
| 5 | 1U Cable Manager | Pc | 15 | 10 | |||||
| Opsyonal nga mga Accessories | |||||||||
| Dili | ngalan | Unit | Qty | Dili | ngalan | Unit | Qty | ||
| 1 | 12-Core Bundled SC Pigtail | Pc | 120 | 4 | SC Adapter | Pc | 1440 | ||
| 2 | 12-Core Bundled FC Pigtail | Pc | 120 | 5 | FC Adapter | Pc | 1440 | ||
| 3 | 12-Core Bundled LC Pigtail | Pc | 240 | 6 | LC Duplex Adapter | Pc | 1440 | ||
Mga Indikasyon sa Palibot sa Operasyon:
Operating temperatura: -40 ℃ ~ + 85 ℃
Temperatura sa pagtipig: -40℃ ~ +85℃
Humidity sa operasyon: ≤85% (sa +30℃)
Relatibong kaumog sa pagtipig: ≤90%–96% (sa 40℃±2℃)
Presyon sa atmospera: 70–106kPa
Kinaandan nga mga Sitwasyon sa Aplikasyon:
Nuclear island I&C equipment room: centrally deployed in core controlled areas such as the HF building and the 220kV switchyard, it carries massive optical signal aggregation of the reactor I&C system, providing low-loss splicing, dispatching and full-link protection between trunk optical cables and I&C equipment, and completely avoiding the impact of strong electromagnetic interference on critical control signals.
Nuclear power data center equipment room: the high-density LC interface model meets 10G and 400G high-speed transmission requirements, supporting high-bandwidth data transmission for the nuclear power production management system and safety monitoring platform, with over 30% port redundancy reserved to meet expansion needs across the plant’s 60-year full life cycle.
Weak-current rooms of nuclear auxiliary buildings: it centrally manages the fiber links of subsystems such as video surveillance, security access control and environmental monitoring within the plant area, avoiding crossover confusion among links and greatly reducing troubleshooting time.
Mubo nga sulat: Ang mga detalye mahimong usbon nga wala’y una nga pahibalo alang sa pagpaayo sa produkto.
Kini angayan alang sa lain-laing mga konsumo sa kuryente scenar ios sama sa residential buildings ug commercial office buildings
Kami komitado sa paghatag dayon, propesyonal nga suporta aron masiguro nga ang imong mga panginahanglanon sa enerhiya kanunay nga matubag sa labing taas nga lebel sa serbisyo.
Ania kami aron pagtubag sa imong mga pangutana ug paghatag sa mga solusyon sa enerhiya nga labing haum sa imong mga panginahanglan.